Research & Publications (selected articles):
- Park, S. H., Lu, Z., Hastings, R. S., Campbell, P. A., & Ebramzadeh, E. (2018). Five hundred fifty-five retrieved metal-on-metal hip replacements of a single design show a wide range of wear, surface features, and histopathologic reactions. Clinical Orthopaedics and Related Research, 476(2), 261.
- Yuan, N., Park, S. H., Luck Jr, J. V., & Campbell, P. A. (2018). Revisiting the concept of inflammatory cell‐induced corrosion. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 106(3), 1148-1155.
- Campbell P, Park SH, Zoller S, Yousuf J, & Nelson SD. (2017). Solid corrosion products in the periprosthetic tissues of a distal femoral endoprosthesis used to treat osteosarcoma. Corrosion : Special Issue on Biocorrosion 73(12):1530-1537
- Campbell P, & Ebramzadeh E. ARMD and Presumed Dangerous!: Commentary on an article by Gulraj S. Matharu, et al.: “Blood Metal Ion Thresholds to Identify Patients with Metal-on-metal Hip Implants at Risk of Adverse Reactions to Metal Debris. An External Multicenter Validation Study of Birmingham Hip resurfacing and Corail-Pinnacle Implants”. 2017, Journal of Bone and Joint Surgery ;99(18)
- Kung MS, Campbell P, Markantonis J, Knutsen A, Ameri B, Park S-H, Ebramzadeh E: Histological characterization of chromium orthophosphate corrosion products from modular total hip replacements. Modularity and Tapers in total Joint Replacement Devices. STP1591, pp428-439. Greenwald AS, Kurtz SM, Lemons JE, Mihalko WM (Eds). ASTM International, West Conshohocken, PA, 2015.
- Kung M, Markantonis J, Nelson SD, & Campbell P. (2015). The synovial lining and synovial fluid properties after joint arthroplasty. Special Issue: Tribological Performance of Artificial Joints. Lubrication. 3(2), 394-412.
- Tan, T. L., Ebramzadeh, E., Campbell, P. A., Al-Hamad, M., & Amstutz, H. C. (2014). Long-term outcome of a metal-on-polyethylene cementless hip resurfacing. The Journal of Arthroplasty, 29(4), 802-807.
- Takamura, K. M., Amstutz, H. C., Lu, Z., Campbell, P. A., & Ebramzadeh, E. (2014). Wear analysis of 39 conserve plus metal-on-metal hip resurfacing retrievals. The Journal of Arthroplasty, 29(2), 410-415.
- K. De Smet, P. Campbell, C. Van Der Straeten: The Hip resurfacing Handbook. Woodhead Publishing, U.K., May 2013
- Van Der Straeten, C., Grammatopoulos, G., Gill, H. S., Calistri, A., Campbell, P. & De Smet, K. A. (2012) “The 2012 Otto Aufranc award: The interpretation of metal ion levels in unilateral and bilateral hip resurfacing.” Clinical Orthopaedics and Related Research, 471(2): 377-85.
- Ebramzadeh, E., Campbell, P. A., Takamura, K. M., Lu, Z., Sangiorgio, S. N., Kalma, J. J., … & Amstutz, H. C. (2011). Failure modes of 433 metal-on-metal hip implants: how, why, and wear. Orthopedic Clinics, 42(2), 241-250.
- Takamura, K. M., Yoon, J., Ebramzadeh, E., Campbell, P. A., & Amstutz, H. C. (2011). Incidence and significance of femoral neck narrowing in the first 500 Conserve® Plus series of hip resurfacing cases: a clinical and histologic study. Orthopedic Clinics, 42(2), 181-193.
- De Smet, K., De Haan, R., Calistri, A., Campbell, P. A., Ebramzadeh, E., Pattyn, C., & Gill, H. S. (2008). Metal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing. Journal of Bone and Joint Surgery, 90, 202-208.
See all Dr. Pat Campbell’s publications on PubMed